New-Indy HRSG
Ontario, CA
Pipe Stress Analysis
Located in Ontario, California, this Heat Recovery Steam Generator (HRSG) underwent thorough Pipe Stress Analysis per ASME B31.1 standards, expertly conducted by JSC Engineers. As contracted through the HRSG manufacturer, we provided comprehensive stress analysis for all Feedwater, Superheater, Ammonia, small bore, and Soot Blower piping. In addition, JSC Engineers also provided the design, selection, and qualification of the pipe supports, ensuring optimal system performance and safety.